Specifications for filters 1.2m to 3.5m diameter Standard Equipment
  • All the equipment strictly according to German standards  DIN 19643 and DIN 19605

  • Construction if vessel is in accordance to British Standards BS4994 and German regulations AD-Merkblatt 2000 for wall thickness

  • Pressure test Certificates according to KSW/KTW, Arbeitsblatt W270

  • The internal liner is Vinylester certified by the German Institute of hygiene (BGA)

  • The height of the funnel over the sand and the height from the funnel to the top is even higher than requested with DIN norms

  • CE certified by TUV Germany

  • Maximum working pressure 2.5 bar static test pressure 3.65 bar ( up to 8 bar available)

  • 5 years warranty on filter shell

  • Sight glass DN200

  • Light to illuminated the water above the filter bed

  • 1x manhole DN 600 on side above nozzle plate

  • 1 x manhole DN 600 on top

  • 2 x Flanges for inlet and outlet in GRP

  • 1x drain, supplied with valve 50mm connection

  • 1 x flange connection on base for air purge, fitted with blanking plate

  • 1 x flanged air relief valve connection (valve included)

  • Nozzle bottom with nozzles

  • Conical diffuser

  • Equipped with lifting ears

  • Leg support

  • Colour is green to RAL 6007

Tank construction
  • Made from polyester resin and fiberglass.

  • Standard isophtalic acid with a chemical protection layer according DIN18820.

  • Inner liner: VINOFLEX

Recommended operation parameters
  • Run phase flow 1 to 20 m3m2hr-1 ( flow rate depends on water type and performance required, max flow for filter is 30 cubm/hr/sqm)

  • Air scour flow 70 to 90  m3m2hr-1 for 5 minutes

  • Back-wash 40 to 45  m3m2hr-1  back wash water fro 1.5 to 5  minutes

 

           

 