Operating guidelines for AFM filters

Run phase  water
flow-rate

cubm hr-1 m

 Air purge all filters at
95 cubm/hr at no more than 0.4 bar pressure

Back-wash water flow
cubm hr-1 m

for grade 1 AFM®

Back-wash water
flow
duration minutes

(2)Back-wash  frequency

Drinking water

optimum

5 - 10

2- 4 minutes

50 - 60

4 - 8

1 to 2 times per day

maximum

10 - 15

Swimming pool

optimum

10 - 15

2 - 4 minutes

50- 60

4 - 8

1  times per week or
every second  week

maximum

15 - 30 

Sewage treatment and industrial effluent

optimum

1 -5

4 to 8 minutes

55 - 65

2 - 4

4 to 8 times per day

maximum

5 - 15

4 - 8

River, lake and sea water

optimum

5 - 10

4 to 8 minutes

50 - 60

4 - 8

2 to 4 times per day

maximum

10 - 30

Aquaculture

optimum

5 to 15

4 to 8 minutes

50 - 60

4 - 8

2 to 4 times per day

maximum

10 to 30

Public aquariums

optimum

5 to 15

3 to 6 minutes

50 - 60

4 - 8

1  times per week or
every second  week

maximum

15 to 30

Landfill Leachate

optimum

1 to 5

8 minutes

55 - 65

4-8

6 times per day          






statistics
in vBulletin