Web sites] | Home | AFM | Ozone | Reverse Osmosis | Swimming Pools | |
||
Conductivity Controller
industrial instruments homepage | buy or view price | manual
|
![]() |
The microprocessor-based conductivity controller is CE and UL certified in compliance to meet international standards against electromagnetic interference. Ideal for power plant, drinking water, boiler and cooling towers, water treatment applications.
Specifications
| Product Code | |
| Conductivity Range | 0.000-1.999,
19.99, 199.9, 1999.9, 5000 µS/cm; 0.00-19.99, 199.9 mS/cm |
| Resolution & Accuracy | 0.001,
0.01, 0.1, 1 µS/cm; 0.01, 0.1 mS/cm & ± 1% Full Scale |
| Cell constants | 0.01, 0.1, 1.0, 10.0 (s/w selectable) |
| Signal output range (0/4 - 20 mA) | Max. 100% Full Scale; Min. 10% Full Scale |
| Temperature Range | -9.9 to 125.0 oC |
| Resolution & Accuracy | 0.1 oC & ± 0.5 oC |
| Sensor (for ATC) | PT100/PT1000 |
| Type of Controller Setting | Limit |
| Pickup/Dropout Delay | 0 to 2000 seconds |
| No. of Relays Maximum Voltage Maximum Current High/Low Hysteresis Band |
2
SPDT; 1 Alarm 250 VAC 3A; 0 to 10% Full Scale |
| Contact Set-points | Lo/Lo; Lo/Hi; Hi/Lo; Hi/Hi (selectable) |
| Alarm Function | Latching / Pulse (software) |
| Power Requirement | 120 or 240 VAC |
| Dimensions | 1/4 DIN (96 x 96 mm) |