NQA
European Commission project  for your
Life & the Environment click here

www.ozone.co.uk

Environmental & sustainable water treatment to save the planet

cool hit counter

factory.jpg (3825 bytes)

| Contact us  | About us Search |  Shop ||

Web  sites  ]   | Home |   AFM  |  Ozone  |  Membrane filtration  | Swimming Pools | ozone monitoring systems from ecosensors mazzie injectors and dryden aqua protein fractionation columns and ozone generaors
 

DA. Mobile ozone generator

Applications buy or view price | pdf file |
    Disinfection  & De-Odourising

start to control surface contaminating bacteria such as MRSA and retro viruses

Ozone Cannon

Eliminates smells and the bacteria responsible for causing the smells.

models :- | DAUV 2700 | DAUV 4000 | DAUV 6800

  • Disinfection of clean rooms
  • Hospital rooms
  • Food process factories
  • Children play areas
  • Air conditioning system
  • Disinfect a house
  • Doctor waiting rooms
  • Hotel rooms
  • Toilets
  • Restaurants
  • Industrial kitchens
  • Swimming pool changing rooms and pool surrounds
  • Cold storage rooms
  • Municipal buildings and ventilation systems

Why

The Dryden aqua UV ozone generators are automatic units unaffected by humidity  that can either be used as portable system or permanently mounted.  For stationary permanently mounted units we recommend that you use the 7 day timer, this allows the unit to work automatically. For example in a swimming pool changing room it may turn on for two hours every night.  By morning the room will have no nasty odours and will have been disinfected. This will have been achieved with no chemicals or work by personnel. The equipment will also run for many years, with only a wipe to clean it every 6 months.

In addition to the UV ozone generators we have one CD ( corona discharge generator) rated at 5000mg/hr. The CD generator is a lower cost, however the corona discharge process is affected by the humidity of the the air.  We recommend that UV generators are used in humid environments, orb the Relative Humidity is above 50%. 

 

How to use

1. Only use when there are no people or animals present in the room. Ozone may also affect plants.

2. Set timer, turn on unit and leave the room. Lock the doors and insure that nobody can enter the room until the ozone generator has been turned off for a period of at least 4 hours.  Use  and ozone monitor to insure that the ozone concentration is less than 0.1ppm

The amount of ozone required to achieve the desired result depends upon the application and the ozone demand of the facility.  However if we take a typical example, of de-odourising and disinfection,  you want to achieve around 1 to 2ppm for  a period of 30 to 60 minutes.

1 g/hr of ozone in 1 cubic meter of air gives approx 460ppm of ozone concentration.  If we take a room 10m x 10m x 3m, volume = 300 cubic meters, 1 g/hr of ozone will give 460/300 = 1.5 ppm.  The DAUV 4000 produces 4g/hr, so in one hour the concentration of ozone will be 1.5 x 4 = 6ppm, assuming that there is no ozone consumption or reduction.  On this basis,  the DAUV will only need to be one for a period of 20 minutes.  This time interval can be used as a starting point,  it may be necessary to increase or decrease the time interval to suit individual applications.  When UV ozone generators are used, and the same air recycled in the room, the ozone level will not continue to increase, it will level out at a few ppm of ozone.

Ozone monitoring

Dryden Aqua have a range of ozone monitors; it is important to monitor the ozone levels to insure that the concentration is below 0.1ppm before anyone enters the room.  For the recommended health & safety levels, click here  We can also provide ozone monitors that can interlock to the generator which will limit the ozone in air level to 0.1ppm.  e.g.,  our ozone switch will achieve this task.

 

General details

Specifications

 

  • Generation method: UV ozone technology. 12 x 380mm UV tubes. UV Tube life: 12-15 months of continuous use.  If only used intermittently,  the equipment will give many years of use before the lamps need to be changed
  • Supply Gas: Ambient Air
  • Ozone output: 4000 mg/hr virtually unaffected by humidity (Unit will produce 5000 mg/hr for first week) ( two other models are available 2700mg/hr and 6800mg/hr
  • Controls: On off rocker switch, remote on/off socket for connection of ozone monitor, and  7 day timer are fitted as standard
  • Dimensions/weight: 610mm L,  230mm W,  170mm H,    weight  10 Kg
  • Electrical: 240 Volt, 3 Amp, 50/60Hz, 120v option available, always use an RCD (residual current devise to break the power supply to unit in the event of leakage to earth)
  • Fan Size: 180 cubm/hr
  • Construction: Stainless steel chassis
  • Maintenance: Under normal 24 hr/day use the DAUV4000 ozone generator tube should be cleaned every 6 months using a moist cloth.
  • Warranty: The DAUV4000 is warranted against defects in materials and workmanship for a period of 2 years from date of purchase. Liability is limited to parts and labour only. Shipping is the sole responsibility of the customer. Dryden Aqua is not liable for damage caused by shipping, misuse, neglect or lack of regular maintenance.